QUESTION
What are the new features incorporated in @ptitude Analyst 9 MR1, MR2, MR3/ Difference between @ptitude Analyst Version 9 & Version 8 ?
ANSWER
SKF @ptitude Analyst Version 9 MR3(v9.0.3)
(Application Modules and Add-ons)
Read Me
Sections in this document include:
SECTION I. GENERAL INFORMATION
- Please visit our web site for maintenance release (updates) information
- Please visit our web site for @ptitude Analyst datasheet which specifies the system requirements - https://www.skf.com/group/products/condition-monitoring-systems/software/aptitude-analyst-inspector.
Under ‘Related documents’, please select ‘SKF @ptitude Analyst product brochure’.
- Microsoft®SQL Server 2008 R2, 2012, 2014, 2016 and 2019 are supported with this SKF software.
- The SKF Group no longer offers product support for the Oracle database. This version of the software was not developed to be used with Oracle and has not been tested with it.
- Windows 8.1, 10, Windows 2016 and Windows 2019 are supported with this software.
- Active Directory is supported with this release.
- If a TCT version prior to version 9.0 is already installed on a system, then TCT must be manually uninstalled before upgrading to Analyst 9.0.
- An updated Analysis and Reporting Manager (ARM) module is supported within @ptitude Analyst MR3. For the missing ARM Sample Data WAV file, please visit https://skftechnicalsupport.zendesk.com/hc/en-us/articles/1500011231781-Example-wav-file-missing-from-ARM-installation-in-Aptitude-Analyst-V9-MR3-
- An updated version of OPC client is also installed and made available with @ptitude Analyst v9 MR3. For further instructions, please visit https://skftechnicalsupport.zendesk.com/hc/en-us/articles/360033856213--SKF-ptitude-Analyst-OPC-Client-v2-0-Guide.
- When using new SKF Sync Drivers, use @ptitude Analyst Configuration Tool to change the setting Software->SKFConditionMonitoring->SKFMachineAnalyst->CommunicationPreferences->RAPITimeout from 5000 to 30000. Also when using SKF Sync drivers in the absence of Windows Mobile Device Center, please make sure the only RAPI.dll files that remain on the system are in ‘C:\Program Files (x86)\SKF\SKF Sync Driver’ folder. Any other residual RAPI.dll files need to be removed from the system.
SECTION II. FIXES
The following Customer reported defects are addressed in this release:
SKF @ptitude Analyst / SKF @ptitude Inspector
4938 |
Trend is properly autoscaled on its low end to 0, when Danger High is removed. |
4966
|
IMx download while clearing all devices has been enhanced to make the user messages more clear when working with multiple IMx services. |
5778
|
Fixed the issue where IMx Control point earlier activated IMx icon service alert / alarm in the bottom icon tray. Now it only impacts alarms related to itself. |
5904
|
Derived POINT MAX function will now accept 2 functions as parameters, without the need to add 0 as a third parameter |
7216 |
Offset Calculator now has more (4) significant figures for Scale and Offset |
14909 |
PDF Report generation and performance improvements. |
15189 |
HAL Support Tab (POINT Setup) is now translated in German |
15397
|
Connection is now re-established with DB/OPC Server when a loss of connection is detected. |
15663 |
Next trace popup menu is now disabled if there is only one Trace on a plot. |
15673
|
Calculation and notification of minimum speed requirement is now correctly shown for Order Tracked IMx points |
15685 |
Allow IMx ID in a range from 1-9999 when using fw 6.0+ |
15686 |
Removal of duplicate Signatures in Tool table |
15687
|
Fixed the issue of missing ‘IMx-8’ DefaultName from registration table for signature "SKFCM-ASDD_Imx8DAD". |
15704 |
Select All button now provides a useful user message for ROUTE selection in Report Editor, when the change is blocked at the database end. |
15712
|
Microlog Inspector Profiles now limited to profiles applicable for logged in User's Customer ID |
15719 |
Now the prompt and results details for Inspection points that have "Shared Alarms” are exported and displayed in the CSV when opened with Excel. |
15720 |
Order is now being reported as per the Phase alarms being Triggered |
15724 |
Improved the download of complete Notes content with the download of Routes. |
15725 |
LMU / IMX Conversion Tool now includes IMx-8 and IMx-16 as a device. |
15727 |
Current Compliance Report is now displaying "Missed Points" section. |
15734
|
Improved Event Log messaging for Microlog Inspector / Microlog Analyzer uploads. |
15737 |
Fixed German translation error for ‘Serial Baud Rate’ in Analyst |
15740 |
Brute force upload of Microlog Analyzer now has Sensor information localized for German and other languages |
15743 |
Fixed the issue with ARM plugin crashing Analyst when using Command line parameters. |
15744
|
In Analyst, unit value for a 3 ch measurement with m/s² units is now same as a 2 channel and single channel measurement POINT |
15749 |
IMx-16 FW warning message in Swedish is now translated. |
15754 |
Fixed the graph for Speed Adjusted alarms. |
15755 |
IMx post processing of speed adjusted overall alarms now allows for deadband |
15758 |
Fixed German translation for ‘Ei’ instead of ‘Ein’ in the Preferences. |
15759 |
Fixed the upload of Alarm Data with more than one average. |
15770
|
IMx devices shown in the POINT properties and MBA are now aligned for the RDC Host as well. |
15776 |
Now Analyst will not load pre-load (v4.99) firmware to IMx-8 nor IMx-16 before upgrading to the latest FW version. |
15779 |
Added an ability to preserve data for a set period of months during archive |
15781
|
OPC v2 – Added an option to turn off timestamp field in Analyst->OPC transfers |
15784
|
Resolved ‘skfOPCService.exe.config missing’ warning message before saving the active database connection after installation. |
15790
|
KBA created for instructions to when deletion is not allowed for the compliance properties from the database. |
15791
|
TCT user message updated for scenarios where TCT is blocked by Firewall |
15792
|
Phase alarms calculation updated to be same for scenarios when new data comes and when POINT properties phase alarms are mildly reconfigured. |
15795
|
The Analyst/OPC Client Configuration (version 2) now retains the configuration file if the Regional Settings change. |
15796
|
IMx-8 category now includes the IMx-8Plus for device selection IMx-16Plus category now includes the IMx-16 for device selection |
15797
|
Percentage band alert and alarm levels are now set as percentages when sent down in the config to IMx. |
Task 12338 |
Discontinuation of Oracle support. |
Task 12339 |
Translations for @ptitude Analyst MR3 development. |
Updated Analysis and Reporting Manager module
OTD 14311 |
ARM Plugin now appears localized when running under an English OS |
OTD 5365 |
When ARM launched from "View linked data", "Save data to hierarchy" operation has improved. |
OTD 7904 |
F11 now changes the graph to full view |
OTD 7154 |
Improvement in arrangement of records in ARM when machine data imported from Analyst |
OTD 7002 |
A way of installing and delivering 'sample data' is in place. |
OTD 4367 |
Data transferred from device is now shown on ARM window on next run. |
OTD 2965 |
Fixed icons for Linked ARM data window. |
OTD 2523 |
Improvements on memory management during operations like Transfer->Microlog ARM data. |
OTD 15751 |
Fixed the crash happening on deleting files after transfer |
OTD 14739 |
Under Analyst the minimize function is now available on ARM main window |
- |
Improved Microlog Sync support under Windows 10 New KBA for SKF Sync drivers. |
OTD 15007 |
Improving the display of component values for single plane displays |
OTD 15778 |
Resolved ARM Mobile Device Viewer locking issue, for scenarios when there are no files in \InternalDisk\Analyser. |
OTD 15775 |
Fixed the functionality of exporting to PDF. |
- |
Improved ARM communications to counter issues in setups where WMDC is being used without ActiveSync. |
SECTION III. ENHANCEMENTS SUMMARY
SKF @ptitude Analyst / SKF @ptitude Inspector
9.0.1 ENHANCEMENTS
OTF 1184 |
Active Directory is now supported in @ptitude Analyst |
OTF 5520 |
Plots, now have the ability to be configured for Notes both prior to earliest reading as well as beyond the latest reading. |
OTT 12169/ OTF 4100 |
Greatly improved overall performance in Analyst, specifically in the data upload/processing functionality. This has led to a reduction of database traffic, yielding much improved user experience in application interaction with Hierarchy and plot refreshes. |
SKF @ptitude Analyst Version 9 MR2(v9.0.2)
(Application Modules and Add-ons)
Read Me Document
Sections in this document include:
SECTION I. GENERAL INFORMATION
- Please visit our web site for maintenance release (updates) information www.skf.com/cm/updates
- Please visit our web site for @ptitude Analyst datasheet which specifies the system requirements - https://www.skf.com/group/products/condition-monitoring/software/skf-aptitude-monitoring-suite/skf-aptitude-analyst-and-skf-aptitude-inspector/index.html.Under ‘Brochures – data sheets’, please select ‘SKF @ptitude Analyst product brochure’.
- Oracle®11g and 12c are supported with this SKF software.
- Microsoft®SQL Server 2008 R2, 2012, 2014 and 2016 are supported with this SKF software.
- Windows 7, 8.1 and 10 are supported with this software.
- For first time Oracle users: Indexes for Oracle should be put in the INDX tablespace. If this tablespace is not created, the database update will be unable to complete. Create the INDX tablespace to allow the Database update to complete successfully. After creating the INDX tablespace, you can run the database update.
- In addition to IMx-8, IMx-16 is also now supported with @ptitude Analyst MR2.
- If a TCT version prior to version 9.0 is already installed on a system, then TCT must be manually uninstalled before upgrading to Analyst 9.0.
- An updated Analysis and Reporting Manager (ARM) module is supported within @ptitude Analyst MR2.
- An updated version of OPC client is also installed and made available with @ptitude Analyst v9 MR2. For further instructions, please visit https://skftechnicalsupport.zendesk.com/hc/en-us/articles/360033856213--SKF-ptitude-Analyst-OPC-Client-v2-0-Guide.
SECTION II. FIXES
The following Customer reported defects are addressed in this release:
SKF @ptitude Analyst / SKF @ptitude Inspector
858 |
Extending sorting capabilities while POINTs are switched in hierarchies. |
969 |
Fixed units on the Shaft Center Line plot |
2286 |
IMx Timezone message has been improved. |
2344 |
Report generation has been optimized to use less resources. |
2376 |
Allow to not print summary information for graphs when printed. |
2377 |
Help file does not tell user what changes are tracked when Log POINT setup changes is activated. |
2477 |
Customize XML Export dialog now prompts the user with more appropriate messages to make sure that the path exists. |
2729 |
Low Frequency Corner displays incorrect in MBA for Order Tracked measurements |
2752 |
SQL Server user creation has been documented in KBAs and Help to assist the users. |
3699 |
File->Open menu item can open a Hierarchy if none is visible. |
4310 |
Saving live data to a live data location, makes the saved POINT disabled by default |
4638 |
Exception reports based on data in last X hours. |
4664 |
License Key Manager now shows appropriate messages when the new key has identical entitlements to the existing key. |
4820 |
Issue corrected that resulted in duplicate Band alarm names. |
5131 |
Customize->Online Settings, when a CMU/TMU device is selected, Data collection method field is now enabled for selection. |
5341 |
IMx and WMx AddOn display the micron unit correctly. |
5778 |
IMx Control point activates IMx icon service alert / alarm in the bottom icon tray |
6212 |
WMx battery POINT default alarm levels are changed appropriately. |
7216 |
Offset Calculator should have more (4) significant figures for Scale and Offset |
10828 |
Microlog Analyzer/NonRoute gE, FFT and Time measurements upload to @Analyst as FFT and Time in POINT setup |
11980 |
@ptitude Analyst report now displays Speed Ratio with a Decimal point |
13728 |
Spectrum/Time plots for two Channel POINTs on switching Axis change to X and Y appropriately for the plots. |
13831 |
Changing Toolbar buttons retains auto-link state |
14146 |
GAP voltage is not correct for Shaft Centerline |
14780 |
Import point with unit "microns" will change to "micron" |
14856 |
Continued to support Thai language changes. |
14923 |
@Analyst Service Manual now contains a section on WMx Service |
15131 |
Translated text on Modbus Slave tab during import of CSV file, |
15189 |
HAL Support Tab (POINT Setup) is now translated in German |
15208 |
Orbit does not rescale based on Detection type |
15220 |
LMU-IMX Converters now transfers FMax as is (with decimals) and not rounded. IMx's now handle End Frequency with decimals. |
15246 |
In Modify by Attribute, 25600 lines are not available for Envelope 3-channel POINT. |
15317 |
Microlog Analyzer Nonroute data traffic light is enabled upon upload in V9 |
15352 |
MAB Import Merge of online data shows sensor unassigned icon (shows traffic light) |
15392 |
Import of statistical band alarms has been fixed to have imported statistical Bands downloaded to an IMX |
15415 |
Missing data for Firmware Version is now verified when dbupdate is run. |
15417 |
Set Speed (Multiple) now updates orders correctly. |
15544 |
IMX download check size limitation has been changed. In essence, the count of the configuration POINTs should not be exceeded. |
15582 |
WMx data collection now records ‘Window’ parameter as per the POINT properties. |
15587 |
With an RDC Client license key an expiration date warning is being provided. |
15656 |
VERSO fix to have @A Client refresh internally while going live and while displaying Hardware Activity. |
15657 |
Modified dbupdate scripts now remove duplicates based on PointId, DataDtg, Status and MeasId in MeasAlarm table. |
15663 |
Next trace popup menu is not needed on one Trace plot. |
15673 |
Calculation and notification of minimum speed requirement is made more clear for Order Tracked IMx points along with directions for applicable selections. |
15674 |
Full Scale is now editable on Battery - XML points for 8800 sensors. This is to allow the user to fix any incorrect values coming from the 8800 configuration setup. |
15681 |
Set Multiple speed now shows correct speed in time plot w/linear speed |
15687 |
DefaultName for "Imx-8" selection has been made more clear. |
15699 |
Fixed an issue with MI service that occasionally caused upload sync to fail after a few days. |
15702 |
@Analyst now checks for Microlog Analyzer Order Track POINTs to a maximum of 200 Orders |
15706 |
IMX service has the low limit for FMax set to 5 Hz now for IMx Order Tracked POINTs when using Firmware Version 2.0 and newer versions. |
15708 |
Under Customize \ Contact Information any form of email addresses are accepted now. It is no more limited to the ‘@*****.com’ format. |
15712 |
For AWS RDC environments the Microlog Inspector Profiles are regulated as per the User. |
15715 |
Compliance reports for Interval based points for Current and Previous period is now based on Take Data value in the POINT configuration. |
15716 |
MODBUS Analog Floating POINT output formats correctly in non-US based Operating Systems |
15718 |
Database versions prior to 5.0.0.0 now upgrade for SQL Server |
15735 |
Fixed a Decision Support issue that, after an upgrade to v9 Inspector data (MCD and Inspection) failed to populate latest readings prior to diagnosis. |
15737 |
German Translation fixed in Analyst for Serial baud rate. |
15741 |
Edit controls on Set Speed Multiple window have been improved. |
Updated Analysis and Reporting Manager module
15684 |
Fixed incorrect imposition of max samples for FFT when doing gE; also corrected way samples combo box can erroneously override the user selection in “samples between…” case |
N/A |
In bearing list, prevent duplicates (based on GUID) |
N/A |
Changes so that objects with multiple records can be used with the Assign bearing functionality, using the first record as the reference. On save, all other siblings have their lists updated from the reference (user is prompted) |
N/A |
Corrected error when importing bearings from online database when running in a German OS (speed was wrong) |
N/A |
Added checks to prompt user over importing a bearing that already exists (by name); options to add to end, overwrite existing, skip or abort. |
N/A |
Added option to delete a bearing from the existing database |
N/A |
Added CSV export options to the bearing list dialog – selected or all |
N/A |
Added hint/status info on current speed when moving mouse over trigger pulse points on waveform plot |
N/A |
Showed nearest speed to cursor (using speed area at top right of plot) if no record speed but there are trigger pulse points |
N/A |
Detection of invalid speeds in waterfalls preventing overflow and range errors when plotting – invalid records automatically ignored by the plot |
N/A |
Added check in the DSP Window waterfall processing to not add speeds when Triggering is true (presence of a trigger channel) but spectrum delta is not “delta RPM” – this is because in this case there are no speeds (values are all zero) and even if we computed them, they are not correct because the zones are not based on the trigger points but on the spacing selection. |
N/A |
Fixed check on selection ranges in DSP Window for waterfall when using fixed spacing, which was not working if there was a trigger channel present. |
N/A |
Fixed problem with alarm bands not being coloured in for grades or showing the alarm level type for alarms, when plotted on a spectrum. |
N/A |
Fixed problem with overall or spectrum RSS being put at the bottom of the plot under certain size constraints. |
N/A |
Fixed display problem for enums whose name is extracted from the RTTI |
N/A |
Fixed incorrect imposition of max samples for FFT when doing gE; also corrected way samples combo box can erroneously override the user selection in “samples between…” case |
N/A |
Work on bearing editor and modified SelectBearing form to work as independent bearing database manager, called directly from the main window. |
SECTION III. ENHANCEMENTS SUMMARY
SKF @ptitude Analyst / SKF @ptitude Inspector
9.0.1 ENHANCEMENTS
15736 |
IMx-16 is now supported in @ptitude Analyst |
|
|
SKF @ptitude Analyst Version 9 MR1(v9.0.1)
(Application Modules and Add-ons)
@ptitude Analyst v9.0.1 MR1
ENHANCEMENTS
- NEW standard support for IMx-8 devices
- NEW support for IMx device communication over Modbus TCP protocol
- Enhanced IMx device Modbus support with availability of 32 Modbus input channels
- Enhanced IMx device Modbus capability with support for floating point data format
DEFECTS
The following Customer reported defects are addressed in this release:
OTD # |
Description |
15261 |
RDC-Host Analyst user level can see assigned customer-based hierarchies. |
15280 |
MAULF file processing with ROUTE property set to limit ROUTE history will not cause failures in updating ROUTE history records. |
SKF @ptitude Analyst Version 9 (v9.0)
(Application Modules and Add-ons)
@ptitude Analyst v9.0
ENHANCEMENTS
- New Windows 10 support (Pro and Enterprise editions)
- NEW integrated HAL Alarms configuration and status display
- NEW HAL Trend plot
- NEW Spectrum/HAL Trend plot
- NEW integrated Contribution Analysis configuration
- NEW Contribution/Profile plot
- HMI configuration usability enhancements
- Improved support for multi-database mode of operation
- Improved configuration of services in multi-database mode
- Improved upgrade support – no longer have to de-install 7.x or 8.x before upgrading
DEFECTS
The following Customer reported defects are addressed in this release:
OTD # |
Description |
676 |
Full Scale Units sent to Microlog Analyzer GX have been formatted to 4 characters. |
1015 |
Printing no longer cuts off edges of the text nor swaps header and footer with some print drivers. |
1059 |
Sideband cursor output now matches Spectrum X axis settings. |
1112 |
Added ability to set color of Exponential Curve Fit overlay separate from Linear Curve Fit overlay. |
1189 |
2-channel POINTs no longer produce plot outputs with blank columns. |
1202 |
Fixed an issue with Transaction Server crashing on bad data. |
2175 |
Removed overdue symbol from disabled POINTs. |
2289 |
Triax Orientation now saved in Modify by Attribute. |
2380 |
Sensor settings are now deleted when a POINT is deleted. |
2774 |
Removed “Internal Temperature” from status for GX and AX Micrologs (this attribute is not supported by the device). |
3256 |
Improved online help for IMx and Monitor topics. |
3411 |
Fixed an issue with recursive HMI links causing a crash in the HMI view. |
3889 |
Changed Phase label to Angle in Orbit graph. |
3972 |
Fixed an ordering isue with Microlog Inspector profiles when a ROUTE / Workspace was deleted. |
3981 |
Fixed an issue that reported MCD readings twice in some configurations. |
4000 |
Newly added barcodes now always sync. |
4129 |
Mixed terms for derived point variables |
5431 |
Fixed a page break issue on reports where the Machine / POINT name were orphaned on the previous page. |
5776 |
Device and channel of IMx devices are now retained during an “update” MAB import. |
5789 |
WMx devices now always follow the wakeup interview when the device is set with Remain on between Measurements. |
5847 |
@A event log now correctly shows the path of problematic MAULF files. |
5985 |
Values are now always displayed for all POINTs in HMI View. |
6358 |
Fixed the logic with the preference to show only Non-Collection data. |
6537, 12752 |
Fixed an issue with Multi MA ROUTE and Exception reports lumping all POINTs together. |
6546 |
SKF Monitor Recovery service now works for all Monitor users and passwords – not just MONITOR account. |
6661 |
HMI cursor now traverses the entire hierarchy list. |
6880 |
Download progress now available for all IMx Service icons. |
7045 |
RDC on-line help now correctly display in local language. |
7540 |
Some RDC users can see Hierarchies that they shouldn't |
8635 |
IMx downloads immediately store data, even if the POINT is currently live. |
8882 |
Compliance report now works for Interval Based POINTs. |
9287 |
Multiple WMx services are now supported. |
9520 |
There is now a lower end frequency limit in Channel Setup for gE and 2 channel measurements. |
9529 |
TS (Service) will not generate Reports to a shared network drive as a scheduled event |
9685 |
POINTs with only notes prior to first measurement time now adhere to the ‘Adjust date/time range to include latest notes’ setting. |
9823 |
Configuration tool now provides an error message if the SQLCMD.EXE file is not found. |
10630 |
User can now clear DMx alarm levels in @A. |
10664 |
Inspection results field automatically changes case for words previously entered. |
12021 |
Support for all special characters the SKF config tool |
10773, 12254 |
Fixed logic in Collection Status report that erroneously reported ‘Collected’ for a POINT that wasn’t. |
10809 |
Notes should not be copied from the set and machine level into an new hierarchy! |
10979 |
Report Dialog Displays the wrong DTS for non Archived Reports |
11706 |
Calculating large amounts of Derived POINT data manually produces an error when rendering the Data View |
12147 |
Configure XML-import will cause XML-file to get extension .sav |
12153 |
Profile owner created with a Backslash in name will cause M/I data not to be processed |
10809 |
Notes are no longer copied into new Machines. |
10979 |
Newly generated reports now always reflect the date / time of creation. |
11706 |
Fixed an issue that resulted in a crash in a POINTs data view when calculating large amounts of historical Derived POINT data. |
12076 |
TCT no longer crashes when uploading large amounts of Microlog Analyzer data. |
12153 |
Profiles no longer accept owners whose names cause processing issues (such as names with backslashes in them). |
12254 |
Overdue / Compliance report now generates a report even if there is no POINTs Overdue. |
12446 |
If nothing shows up in overdue/compliance report, the "overdue as of" text is missing |
12539 |
Importing of pre-2013 MR3 MAB with Transient data now set the device of the Transient Event. |
12552 |
MBA now limits the number of lines of Triaxial POINTs to 6400. |
12591 |
Graphs plots now show up on emailed reports. |
12640 |
Add documentation for @A / TCT to install Windows Mobile Device Center in installation instructions |
12688 |
Fully translated Russian patch instructions. |
12702 |
MBA now works for Channel Settings / Sensor Axis |
12770 |
Fixed French translation isues |
12781 |
Fixed an issue in a multi-cultural environment where a previous user’s localized strings were being output in reports for the current session (an English user was getting Spanish column headers). |
12793 |
Calendar based ROUTEs now always correctly update Upload Status. |
12815 |
Database update failed in Hungarian_CI_AS collation setting |
12807, 13766 |
Oracle now displays latest N measuments correctly. |
12842 |
6400 FFT & TIME IMx data now processes correctly when data is provided in MAULF form. |
12887 |
Fixed an issue with some print drivers where the Band cursor obscured the data line. |
13076 |
MBA now sets Band Alarms correctly for 2nd channel. |
13137 |
ROUTE overdue message no longer reset when an empty ROUTE is uploaded. |
13157 |
ROUTE History now calculated properly for MCD POINTs with Non-Collection events. |
13198 |
Fixed an issue with missing trigger timeout options in WMx Speed POINTS. |
13255 |
Clear Alarm Non Collection and Exclude Non Collection from report POINT attributes no longer exported when Force v6.1 Format option is enabled. |
13266 |
Communication protocol for Microlog Analyzer now defaults to USB on new installations. |
13286 |
Addressed an issue that resulted in some WMx devices not connecting properly after upgrade. |
13335 |
WMx devices no longer allow a timeout of 0. |
13342 |
Fixed ‘FT IR Spec. Soot’ label in Portuguese. |
13386 |
Fixed an issue with some configurations of Transient not properly sent to IMx devices. |
13388 |
Fixed issues with non-Gregorian based calenders (for example Thai/Buddhist). |
13478 |
In SysInfo dialog, right click Acknowledge functionality has been improved. |
13500 |
MBA now allows for the global setting of MCD alarms. |
13508 |
Scheduled On-Alarm Messages now include Machine Name as well as POINT name. |
13533 |
New users have their toolbar icons displayed in 2 rows rather than 7. |
13769 |
Microlog Inspector sync operation now provide device name and GUID for Serial Number. |
13770 |
Imports of older MAB files with incorrect Sensor data for Microlog POINTs no longer halt the import process. |
13811 |
Addressed an issue with missed Non-Collection POINTs during MAULF processing. |
SKF @ptitude Analyst Version 8 MR3(v8.1.3136)
(Application Modules and Add-ons)
@ptitude Analyst v 8.1.3136 MR3
ENHANCEMENTS
- Oracle 12c support
- SQL Server 2014 support
- Windows 8.1 support
- Windows 2012 R2 support
- Supports IMx FW 5.0 and higher
- Modbus output of SKF Enveloped Acceleration measurement POINTs
- Multiple Measurement POINTs per Modbus channel
- Ability to set speed across multiple FFTs simultaneously
- Ability to clear alarms when last measurement is a non-collection event.
- Ability to exclude disabled POINTs and POINTs whose last measurement is a non-collection event from reports.
- Automatically adjusts timestamp of Microlog Analyzers when connected.
- Optionally adjust measurement timestamps in Transaction Service when measurement timestamp is out of tolerance.
DEFECTS
The following defects are addressed in this release:
OTD # |
Description |
1031 |
Overdue flags are now cleared as new data is added |
2282 |
Phase data is no longer stored for IMx POINTs unless save data is set |
2417 |
Copying an LMU POINT now copies named sensor settings |
2482 |
DMx POINTs now appear in Exception reports |
2666 |
Low Frequency cutoff for gE POINTs are set to 0. |
2679, 5744, 8826 |
@A will no longer re-order toolbars when extra-long toolbar rows are created. |
3059 |
Topology plot nows remember between “speed” and “time” |
4702 |
Can now generate Microlog Inspector Upload Scheduled Events assigned to an @ptitude Analyst account rather than the Transaction Service. |
5906 |
Memory leaks in HMI views have been fixed. |
5991 |
Toolbar buttons now default to the correct enabled state on application start |
6002 |
HMI Configuration no longer reorders tree control items |
6006 |
Memory leaks in live graphs have been fixed. |
6214, 9785 |
FTF Frequency markers for FFTs with low speed relative to end frequencies no longer show ‘0’. |
6281 |
Accessing a non-default database through command line now properly loads all modules. |
7793, 10518 |
Alert and Danger lines on Trends now properly show in all instances. |
8508 |
Autoscale now functions correctly moving from POINT to POINT. |
8524 |
All Vibration Velocity amplitudes in multi-channel graphs now show properly. |
8674 |
Phase alarm calucation is now correct for all 4 quadrants. |
8737 |
Brute force upload of Microlog Analyzer version 4.0 or higher now upload all measurement history. |
8757 |
Delays in getting to a ‘Microlog Ready’ state when connecting to a Microlog Analyzer version 4.0 or higher when large amounts of OffRoute data are present has been fixed. |
8813 |
Protection Threshold toolbar icons no longer appear in @ptitude Inspector or @ptitude Analyst for Microlog Analyzer. |
8883 |
A column for the Send Text setting has been added to the Contacts manager. |
8884 |
Compliance report no longer include disabled points as ‘not completed’. |
8927 |
Reset Indicator functionality is now properly restricted based on Access Level for all devices. |
8934, 9755, 10608 |
MAB File import processing has been improved. |
8951 |
Derived POINT MBA labels are now clearer. |
9010 |
Hierarchy view no longer crashes when receiving large amounts of data (such as a DMx Protection trigger data dump). |
9320 |
WMx POINTs now store speed correctly in all instances. |
9434 |
Archiving now works on Non-Collection measurements. |
9687, 9710 |
TCT is now more responsive if connection to the internet is lost when connecting to Transaction Server on the cloud. |
9723 |
Speed Reference, Process Gating and Digital Gating select dialogs now always appear properly for IMx POINTs. |
9819, 9820, 9821,10379 |
IMx configuration now accounts properly for channel count. |
9833 |
Several conditions that have resulted in missed WMx measurements have been addressed. |
9836 |
BOV values now properly set when merging or updating IMx data via MBA import. |
9949, 10878, 10883, 11214, 11229 |
Improved German translations. |
10139 |
Microlog Analyzer status now properly shows firmware versions 4.0 or higher. |
10164 |
Trend Plots now print properly. |
10227 |
General improvements to installation for domain environment have been made. |
10322 |
Band Alarm Sets update properly for tri-axial measurement plots. |
10517 |
POINT Setup validation for End Frequency cutoff now work properly for CPM settings. |
10730 |
ROUTE History % Complete now calculates properly. |
10743 |
(Enhancement) Microlog Analyzer Upload option ‘Upload measurement history” now remembers last setting. |
10746 |
Brute force of CMVA Microlog NonRoute data uploads ALL POINTs under 1 POINT and all measurements as Acceleration |
10790 |
@A now forces Low Cuttoff Frequency to 0 when uploading Microlog Analyzer NonRoute gE measurements |
10792 |
The functionality of DMx Transients has been restored. |
10803 |
Trend/Spectra plots now print properly when Info area has been turned off. |
10826 |
All reports now show content when delegated to the Transaction Service. |
10829, 10835, 11480 |
Performance has been improved when retrieving measurements. |
11334 |
Upload: # POINTs Processed Event Log message has been restored. |
11509 |
Brute Force upload shows incorrect detection label in FFT Plots. |
11510 |
Brute Force upload places Non-Route machine in the Hierarchy of the Microlog Configuration instead of the currently selected Primary Hierarchy. |
11546 |
MBA of WMx Number of Averages now matches POINT Setup (1-20). |
11589 |
Brute Force upload now correctly sets the Serial Number of the device in the measurement. |
11671 |
Added ability to exclude disabled POINTs from Last Measurement, Inspection, and Measurement Statistic reports (always excluded for Exception and Overdue reports). |
12536 |
Compliance reports now account correctly for non-collection events. Machine OK POINTs are counted towards the total; all other events (Machine Not Operating; Condition Not Met) decriment the total count by each POINT. |
12567 |
Processing of MCD POINTs with Shared alarms now accurately reflect the alarm condition. |
SKF @ptitude Analyst Version 8 MR2 (v8.1.2003.3)
(Application Modules and Add-ons)
@ptitude Analyst v8.1.2003.3 MR2
ENHANCEMENTS
This release was bug fixes only. No enhancements were added.
DEFECTS
The following defects are addressed in this release:
OTD # |
Description |
1879 |
Copy function for Conditional POINTs has been modified. When copying POINTs with Conditional, Speed, Process, and Digital POINT references, the references will adjust to the newly created source POINTs if the source POINTs are copied at the same time. |
3998 |
Mag/Trend plots, when printed, now use the entire page. |
4097 |
Machine Not Operating notes are no longer generated when the ‘Machine OK’ button is pressed on the Microlog Inspector. |
6193 |
Machine Not Operating notes are no longer generated when a Non-collection event is generated (such as condition not met for Derived POINTs) on the Microlog Inspector |
6528 |
Derived POINT calculations are now prevented for disabled POINTs. |
6974 |
ARM: Can add speed to all types of data |
7020 |
ARM addon - default Word reports now point to the right location for report templates |
7153 |
ARM: CTC CSV files can now be directly unloaded from Microlog. |
7184 |
ARM: Quick FFT data can now be overlaid |
7257 |
ARM: Data Collector Interface now works with Microlog v4.0 |
7320 |
ARM: Balancing Word reports now show both polar plots |
7325 |
ARM: DSP Window controls now function properly after analyzing trigger channel |
7326 |
ARM: The first spectrum in waterfall from Hz to CPM can now be changed. |
7404 |
ARM: Ru Cd WAV files collected with AX firmware version 4.0 now have Y-Axis options. |
7405 |
ARM: RuCd CSV File - Microlog v4 – The message when file contains no data is now correct. |
7531 |
ARM: Can now convert gE spectrum to Cepstrum if alarm assigned |
7706 |
Scheduled reports designated to the Transaction Service now email correctly. |
7707, 8184 |
Digital Gating has been restored to the IMx Threshold POINT Setup tab. |
7762 |
IMx POINTs set with Order Tracking now works properly with IMx firmware version 2.0. |
7781 |
POINTs in alarm are now combined in a Scheduled ‘On Alarm’ event report. |
7802 |
ARM DSP Window Hz vs Orders are now correct when producing Single Spectrum |
7804 |
Microlog Inspector Uploads (Sync operations) now triggers scheduled events. |
8074, 8401, 8423, 8425, 8527 |
Some missing translations in German have been addressed. |
7895 |
ARM Acceptance Test File Manager can be exited without error. |
8099 |
ARM - Balance files with polar data from Microlog can now be unloaded. |
8100 |
ARM Mobile Device Viewer in ARM now uses the correct icons. |
8103 |
ARM Excel export – now supports XLSX format and files with greater than 65535 rows – Requires Excel 2007 or later. |
8104 |
ARM plug-in - Bearing Database dialog is now correct for German translations. |
8101 |
The rebuild users script has been fixed for non US localization. |
8149 |
IMx Order Track POINTs now correctly prevents the configuration of downloading of band alarms as the firmware does not support this feature. |
8183 |
Improved the speed of displaying MCD measurements views. |
8232 |
ARM 2.0 no longer uses the "Analysis and Reporting Manager data" folder. |
8233 |
ARM-Add-on is now able to Change Data Source in Mobile Device Viewer when launched directly |
8239 |
ARM 2.0 Swedish translation now reads all CSV files from Microlog |
8250 |
ARM CTC Template Generator from ARM now shows gE options |
8257 |
POINT Overdue Events now generate 1 event per overdue POINT. |
8260 |
The ability to manual archive multiple measurements has been restored. |
8262 |
ARM 2.0 - CTC template folder setting is now correct on new installs. |
8294 |
When configuring Scheduled Alarm Events, selecting a top hierarchy tree element now automatically selects all children, hidden or shown. |
8307 |
ARM add-on: gE spectrum now allow applying bearing and speed. |
8310 |
ARM: DSP Window now allows selection of trigger channel in all instances. |
8318 |
ARM - Displayed overall level now changes detection when you change detection for spectrum. |
8365 |
Live Spectrum now properly displays 0 for RPM when the Tach input is zero. |
8366 |
ARM does not set up x-axis values correctly from Analyser CSV files captured using CPM |
8372 |
ARM: Now can upload Non ROUTE from all Micrologs. |
8374 |
The IMx-Transient properties tab has been restructured to better handle long translations of German prompts. |
8381 |
The issue with Inspection reports occasionally generating blank or missing reports has been fixed. |
8384 |
ARM: Overall level displays now all use correct units. |
8390 |
ARM: All standard units are now translated |
8405 |
The Overall Alarm overlay now shows up correctly in Trend plots on reports. |
8411 |
Performance improvements have been made to measurement and plot displays. |
8417, 8577 |
ARM: Importing bearings now function correctly. |
8422 |
Cyrillic fonts are now properly displayed on the splash screen. |
8424 |
Russian characters can now be entered as Report names. |
8458 |
ARM: Bode or Nyquist now allow switching back to balancing plot. |
8462, 8625 |
WMx Service no longer creates occasional event log ‘Include Good Alarms’ and ‘Invalid Timestamp’ events. |
8472 |
Performance improvements have been made when deleting large amounts of measurement data. |
8522, 8523 |
Improvements have been made in the Microlog Inspector service when dealing with time out issues. |
8545 |
The Microlog Analyzer upload tab remains disabled until the Microlog is ready to communicate. |
8548, 8549 |
Alarm calculations have been improved to prevent situations where traffic lights occasionally do not update. |
8562 |
The ROUTE overdue status now works for all ROUTEs when using the ‘Allow Multi-hierarchy support on DADs’ feature. |
8563 |
The IMx device configuration now allows negative Zero Offset to be entered. |
8589 |
The Configuration Tool now allows new Transaction Services to be added without turning off all currently running Services. |
8590 |
The Configuration Tool now allows database connections to be switched without turning off all services. |
8610 |
The 64-bit version of the MS SQL Server Express installer has been added to the DVD. |
8611 |
The default password to SA has been strengthened to simplify installation, prevent confusing error messages and to meet Microsoft database security standards. |
8613 |
The Microlog Analyzer default protocol now defaults to ‘USB’. |
8616 |
The MCD Statistical Alarm prompt for ‘Temperature Danger’ has been corrected for Portuguese. |
8622 |
ARM: Balancing reports now automatically calculate for correction weight. |
8632 |
IMx Self Threshold limits can now be set for all POINT types in Modify by Attribute. |
8637, 8651 |
IMx Self Gating limits now correctly convert English Unit POINTs. |
8694 |
The Machine Not Operating button on the Microlog Inspector now always produces only one coded note in @ptitude Analyst. |
8715 |
Derived POINT calculations are now halted correctly when the Derived POINT is disabled or the option is turned off in Monitor. |
8808 |
Fixed an issue where some in some instances the Microlog Analyzer upload failed to process data. |
8892, 8893 |
Fixed some issues with Microlog Inspector licensing in RDC environments. |
Comments